DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-110test board
A
test board
Help Messages
If the system technician presses HELP after entering "test board" the following message
will be displayed:
Enter board location, [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the format for the board location is incorrect, the following error message will be
displayed:
Port/Board invalid
If the EPN in which the specified board resides is not available, the following message
will be displayed:
EPN is not available
If the specified board is not configured in the system, the following message will be
displayed:
Board not assigned
If the request for all maintenance objects associated with the board fails, the following
message will be displayed:
No MO in this board
If no tests can be found for the associated MO, the following message displays:
No tests for this MO
If the specified board is a Switch Node Interface (SNI) board which resides on the active
Port Network Connectivity (assuming PNC is duplicated) and a long test has been
specified, the following message will be displayed:
Must busyout specified object first
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the user
to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit