Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-396test tdm
8
test tdm
This command tests all the time slots on a bus associated with a PPN or an EPN.
1. If no alarms are registered against the maintenance object then the test sequence is run only once. The
long clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence.
2. Refer to the Report Scheduler and System Printer feature specification for more details.
Action/
Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test tdm
pn number
short
long
repeat number
clear
schedule
nn
= number of the port network to
have its TDM bus tested. Both
halves (“a” and “b”) of the TDM
bus are tested.
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
2
Examples:
test tdm port-network 1 l
test tdm port-network 2 sh r 2
test tdm port-network 2 sh sch
test tdm port-network 1 l r 25
test tdm port-network 2
test tdm port-network 1 c
init
inads
craft
Test
Sequence
= short;
Repeat = 1
none