DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-628EXP-INTF (Expansion Interface Circuit Pack)
10
1031 ABORT If the Expansion Interface circuit pack is in an EPN and is active and is in
slot A01 or B02, this test CANNOT be executed. If the lightwave
transceiver loop around is activated, it is impossible to deactivate it.
1. If a Standby Expansion Interface circuit pack pair exists, make that
pair active via the set expansion-link PCSS command, where PCSS
is the address of a Standby Expansion Interface circuit pack.
2. If the Expansion Interface Link switch is successful, the lightwave
transceiver Loop Around Test may now be executed on the original
Expansion Interface circuit pack in the EPN.
1139 ABORT The Packet Bus in an Expansion Port Network (Port Network 2 or 3) has a
major alarm against it. This test needs to use the alarmed port network’s
Packet Bus.
1. Resolve the Packet Bus alarm.
2. Retry the command.
1141 ABORT The Packet Control circuit pack is out-of-service.
1. Determine if the Packet Control circuit pack is busied out by checking
the Hardware Error Log to see if Error Type 18 has been logged
against PKT-CTRL. If Error Type 18 is present, release the circuit pack
via the release packet-control command, and retry the command.
2. If the Packet Control circuit pack is NOT busied out, refer to PKT-CTRL
(Packet Control circuit pack) Maintenance documentation for the
recommended repair procedure.
1144 ABORT The Packet Bus in the Processor Port Network has a major alarm active
against it. This abort code only appears when the test is run in an EPN.
1. Resolve the alarm in the PPN.
2. Retry the command.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2060 ABORT The link on the Packet Bus being used to perform the test has failed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, check for problems with the Packet
Control circuit pack (look for PKT-CTL errors).
Table 10-213. TEST #242 Expansion Interface Lightwave
Transceiver Loop Around Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page