DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-60display errors
8
Form output
After you complete the options screen, the system displays a 1- or 2-page
Hardware Error Report. To toggle between the pages and to exit the report, use
the keys described below:
For 513 and 715 terminals, use F8 for NEXT PAGE and PREV PAGE commands
For all other terminals, use F7 for NEXT PAGE and PREV PAGE commands
Use Esc for the CANCEL command
The figure below is an example of an Hardware Error Report -- Active Alarms,
without the high-resolution qualifier in the command line.
Field descriptions
Port Lists the location codes for the alarmed object, as follows:
Circuit packs locations display as:
cabinet-carrier-[slot]-[circuit]. Example: 01C702.
Port network locations display as: port network number-bus.
Example: PN 02B. PN 02 = Port Network (PN) number and A
or B = bus.
Maintenance
Name
Lists the logical name of the maintenance object with an error
logged against it.
Alt Name Identifies the location of maintenance object, as follows:
Station = extension number
Trunk = Group number (78/__) or group and member
numbers (78/01)
Private CO Line = private CO line (P) and group number
(P/xxx)
display errors Page 1 SPE A
HARDWARE ERROR REPORT - ACTIVE ALARMS
Port Mtce Alt Err Aux First Last Err Err Rt/ Al Ac
Name Name Type Data Occur Occur Cnt Rt Hr St
01C0702 ANL-LINE 311 257 01/31/09:20 01/31/20:26 255 256 255 a y
01C0701 ANL-LINE 1051 257 01/31/20:26 01/31/20:26 4 0 4 a y
01C0703 ANL-LINE 1053 257 01/31/20:26 01/31/20:26 4 0 4 a y
01A TDM-CLK 0 0 01/31/20:34 01/31/20:34 1 0 1 a n
01C1505 CO-TRK 078/001 3329 57408 01/31/20:26 01/31/20:27 5 300 5 a y
01C1505 CO-TRK 078/001 1537 01/31/20:26 01/31/20:28 5 150 5 a y
02A0201 TONE-PT 0 01/31/20:34 01/31/20:34 1 0 1 a y
PN 02B TDM-BUS 18 0 01/31/14:53 01/31/21:12 1 0 1 a n
Command successfully completed