Page 10-925PDMODULE, TDMODULE (Data Module)
10
2500 ABORT Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, escalate the problem.
3004 ABORT 1. This error could be caused by the switch setting of the PDM. Verify that
the switch on the PDM is set to the "remote loop" position. When the
remote loop around test is completed, return the switch to the "off"
position.
2. This error could be caused by the Network Control Data Channel. Look
for DATA-CHL errors in the Hardware Error Log.
3. This error could also result if no data equipment is connected to the data
module. Verify that (a) the data equipment is properly connected to the
data module, (b) that power is available to the data equipment, and that
(c) the data equipment is powered on.
4. This error could also occur if the baud rate of the data module is set to
19.2 Kbps since the Network Control circuit pack used by this test does
not support baud rates greater than 9600 bps. Verify that the baud rate
of the data module is set to 9600 bps or less.
1040 FAIL Data received from remote loop back does not match data sent.
1. Check for faulty wiring.
2. Replace the data module and repeat the test.
3. If the test fails, replace the Digital Line circuit pack associated with the
data module and repeat the test.
4. If the test continues to fail, escalate the problem.
1070 FAIL Internal software response.
1. Wait one minute and attempt the test again.
2. If the same error persists after five attempts in one-minute intervals,
escalate the problem.
1072 FAIL Poor response from auxiliary channel.
1. Test the Network Control (Netcon) circuit pack using the test
data-module command.
2. If the test fails, replace the Digital Line circuit pack.
3. If the test continues to fail, escalate the problem.
1073 FAIL Internal System Error.
1. Wait one minute and attempt the test again.
2. If the same error persists after five attempts in one-minute intervals,
escalate the problem.
Table 10-310. TEST #175 Data Module Internal Loop Around Test — Continued