Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-618EXP-INTF (Expansion Interface Circuit Pack)
10
Expansion Interface Fiber Out-of-Frame (FOOF)
Query Test (#238)
This test is a request to an Expansion Interface circuit pack to determine if it is
currently detecting the framing sequence on the incoming fiber data stream. If it
cannot detect this framing signal, the Expansion Interface circuit pack is not able
to establish a link with the opposite Expansion Interface circuit pack.
0NO
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board (error 131).
Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (error 1538). If hyperactive, use the reset board PCSS
command.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
the board and retest.
Table 10-210. TEST #238 EI Fiber Out-of-Frame Query Test
Error
Code
Test
Result Description/Recommendation
ABORT Internal system error
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2026 ABORT Expansion Interface circuit pack responded with an unknown reply.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 10-209. TEST #237 EI Neighbor Query Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page