DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-430DIG-LINE (Digital Line)
10
There is no visible display on a station for the other background or
demand download actions. As described below, the "status station" and
"status attendant" screens can be used to check the download status of a
specified terminal.
Status of Parameter Downloads
The "status station" and "status attendant" screens display the current download
status of individual 84xx, 603, and 301B1 terminals in the Download Status field.
The possible download states are:
Possible reasons for terminal being not downloaded include:
Terminal is off-hook.
Terminal detected a bad checksum.
Terminal detected a bad or missing EEPROM (refer to hardware error log).
Terminal is busy programming data from a previous PROGRAM message.
Terminal is in the Programming Disabled state.
Terminal is in the Local Program Options Mode.
Terminal is disconnected or out of service (use status station command).
Hardware Error Log Entries and Test to Clear
Values
Table 10-139. Terminal Download Status
Status Terminal Down Load State
Complete Terminal successfully downloaded sometime in the past.
Pending System waiting to download the terminal. This may require the
execution of a background periodic test which could take more
than an hour. A demand download as described above may also
be used to initiate an immediate download.
Not Applicable Not a programmable terminal.
Table 10-140. DIG-LINE Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40987 None WARNING OFF
Continued on next page