DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-115ANN-PT (Announcement Port)
10
1 to 254 FAIL Test failed. The error code indicates the number of byte
count errors found by the Tone Detector.
1. Reset the circuit pack via the reset board PCSS
command and then run this test again. If the test
continues to fail, replace the circuit pack (see
Warning).
2. If there are recurring alarms on this port caused by
this test failing, replace the circuit pack even if Step
1 works (see Warning).
!
WARNING:
Replacing the circuit pack results in loss of
integrated announcements. Refer to "General
Notes" near the beginning of this Maintenance
procedure.
255 FAIL Test failed. The Announcement Port and the Tone
Detector never synchronized. Check for active GPTD-PT
errors, and refer to "GPTD-PT [General Purpose Tone
Detector Port (CPTR)]" Maintenance documentation to
diagnose them first.
1. If there are no active GPTD-PT errors, reset the
circuit pack via the reset board PCSS command
and then run this test again. If the test continues to
fail, replace the circuit pack (see Warning).
2. If there are recurring alarms on this port caused by
this test failing, replace the circuit pack even if Step
1 works (see Warning).
!
WARNING:
Replacing the circuit pack results in loss of
integrated announcements. Refer to "General
Notes" near the beginning of this Maintenance
procedure.
Table 10-41. TEST #206 Playback Speech Memory Array (PSMA) Test —
Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page