Maintenance Object Repair Procedures
Page 10-811MET-LINE (MET Line)
10
Table 10-272. TEST #35 Port Diagnostic Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at one-minute intervals a maximum of
five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The
port may be busy with a valid call. Use the display port
PCSSpp command to determine the station extension,
attendant number, or trunk group/member number of the port.
Use the status station, status attendant, or status trunk
command to determine the service state of the port. If the
service state indicates that the port is in use, then the port is
unavailable for certain tests. (Refer to the "Status Commands"
section in Chapter 8, ‘‘
Maintenance Commands and
Trouble-Clearing Aids’’ for a full description of all possible
states.) You must wait until the port is idle before retesting.
Attendants are always in use (off-hook) if the handset is plugged
in and the port is not busied out.
1. If the port status is idle, then retry the command at
one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page