Maintenance Object Repair Procedures
Page 10-1493UDS1-BD (UDS1 Interface Circuit Pack)
10
Table 10-503. TEST #1209 DS1 Board Loopback Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the
test ds1-loop PCSS ds1/csu-loopback-tests
command at
1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1005 ABORT DS1 Board Loopback Test cannot be executed in the current
configuration. To run this, the TN464F or later suffix UDS1 must be
administered for 24-channel operation. The "Bit Rate" field on the DS1
circuit pack administration form must be set to "1.544" for 24-channel
operation.
1015 ABORT Ports on the UDS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board PCSS command to put all trunks or ports of
the UDS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
3. If the test continues to abort, escalate the problem.
1039 ABORT The UDS1 Interface circuit pack is providing timing for the system.
Executing this test could cause major system disruption. If the UDS1
Interface circuit pack needs to be tested, set the synchronization reference
to another DS1 Interface circuit pack or to the Tone-Clock circuit pack via
the following command sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization PCSS command.
3. Lastly, issue the enable synchronization-switch command. Then
rerun the test. If the test aborts again, a different ABORT error code will
be generated. Follow the recommended maintenance procedures for
that error code.
1950 ABORT Another loopback/span test is already executing on the DS1 boardor the
board is in a network requested loopback mode (Line loopback or Payload
loopback). The hardware error log will indicate whether a Customer
Loopback Jack Test, Far CSU Loopback Test, or the One-Way Span Test
is executing or if the board is in line loopback or payload loopback mode.
Only one long-duration loopback/span test can be active at a given time.
Thus, if a loopback/span test is already active, that test must be terminated
via the
test ds1-loop PCSS end-loopback/span-test
command in order to
execute this test.
Continued on next page