DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-973PI-PT (Processor Interface Port)
10
1029
1030
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2051
ABORT Refer to the STBY-SPE Maintenance documentation for a description of these
error codes.
12 FAIL Processor Interface circuit pack reported that the Loop Around Test failed.
1. Retry the test. If the test continues to fail, try resetting the circuit pack via
the reset interface PCS command.
2. If test continues to fail, replace the TN765 circuit pack. Refer to Chapter 6,
‘‘Reliability Systems: A Maintenance Aid’’ for instructions on how to replace
an SPE complex circuit pack.
PASS TN765 Processor Interface Circuit Pack Loop Around Test passed. The
hardware associated with this port is functioning properly.
Table 10-330. TEST #404 Standby Processor Interface Port Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page