Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-701INADS (INADS Link)
10
4 0 INADS did not answer the alarm origination call.
1. Verify INADS is up and running.
2. Verify the INADS phone number and switch product id are correct via
the Maintenance-Related System Parameters Form.
3. Enable alarm origination via the Maintenance-Related System
Parameters Form and test the PR-MAINT (Maintenance/Tape
Processor) by issuing the test processor a|b command. If PR-MAINT
Tests #102 and #103 do not pass, then refer to PR-MAINT
(Maintenance/Tape Processor) Maintenance documentation.
4. Retry the command.
5 0 No INADS phone number administered.
1. Administer the INADS phone number via the Maintenance-Related
System Parameters Form.
2. Retry the command.
6 0 INADS did not send the acknowledgment message to the "test inads
alarm" message.
1. Verify the INADS phone number and switch product id are correct via
the Maintenance-Related System Parameters Form.
2. Verify INADS is up and running.
3. Retry the command.
7 0 INADS sent a negative acknowledgment to the "test inads alarm"
message.
8 0 Internal system error; system received an invalid return code.
9 0 Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
10 0 There is already a test inads-link command in progress.
1. Wait 10 minutes for the present command to finish.
2. Review the results of the present command by viewing the Error Log
and selecting the category "inads-link."
11 0 The switch is trying to report alarms to INADS. The test cannot be run at
this time.
1. Wait 10 minutes and retry the command.
Table 10-234. INADS Link Error Log Entries Test — Continued
Error
Code
Test
Result Description/ Recommendation