Maintenance Commands and Trouble-Clearing Aids
Page 8-321test alarms
8
Field descriptions
When encountering errors in preparing a particular object to be tested (not
inserted, contention, etc.), an error message display in the TEST RESULTS
section of the output form.
ALARM ENTRY section
Port Port location of alarmed object (cabinet-carrier-slot-circuit); same
identifier as alarm log
Maintenance
Name
The name of the maintenance object
On Board Fault detected is on the associated circuit pack (y) or off board
(o).
Alt Name Terminal extension numbers or trunk group numbers
Alarm Type Major, Minor, or Warning
Service State Current service state of the station and trunk ports: RDY (ready for
service), OUT (out of service), or IN (in service).
Ack Whether alarm has been acknowledged by the first and second
OSS telephone numbers, respectively.
Date Alarmed Day, hour, and minute of alarm.
Alarm Count Count of the current alarm entry versus the total number of alarms
to be tested.
test alarms Page 1
ALARM ENTRY
Port Maintenance On Alt Alarm Svc Ack? Date Alarm
Name Brd? Name Type State 1 2 Alarmed Count
01C03 UDS1-BD n WARNING 03/06/16:48 1/4
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C03 UDS1-BD 138 NO BOARD
01C03 UDS1-BD 139 NO BOARD
01C03 UDS1-BD 140 NO BOARD
01C03 UDS1-BD 141 NO BOARD
01C03 UDS1-BD 142 NO BOARD
01C03 UDS1-BD 143 NO BOARD
01C03 UDS1-BD 144 NO BOARD
01C03 UDS1-BD 145 NO BOARD
01C03 UDS1-BD 146 NO BOARD
Testing completed for this object.