Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1010PMS-LINK (Property Management System Link)
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. The PMS Link has been busied out for system technician-demanded
maintenance via the busyout pms-link command. The link is torn down.
Enter the release pms-link command to restore the link.
b. The Link Retry Test (#215) fails. The Aux Data field contains either the
Channel ID of Data Channels on Network Control circuit pack (that is, 3 for
Channel 01, 4 for Channel 02, 5 for Channel 03, 6 for Channel 04) or an
Error Type of 99 indicating no data channels are available for setting up
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
3. Is any integer.
PMS Link Maintenance Error Log Entries
Error Type Aux Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test pms sh r 1
18 (a) 0 busyout pms-link WARNING OFF release pms-link
257 (b) 0-6,
99,
255
Link Retry Test (#215) MINOR/
WARNING
2
OFF test pms-link l
513 (c) 0-6,255 None test pms-link
769 (d) 0-6,255 None
1025 (e) 4x
3
None
1281 (f) 1x
3
None
1537 (g) Nx
3
None
1793 (h) 0-6,255 None test pms-link
2049 (i) 0-6,255 None
2305 (j) 5x
3
None release pms-link or
test pms-link
2561 (k) 0-6,255 None test pms-link
2817 (l) 10x
3
20x
3
30x
3
None
3073 (m) 7x
3
None
3841 (n) 2x
3
None