DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-378DATA-CON (Network Control Driver)
10
Error Log Entries and Test to Clear Values
Note:
a. As previously described, the DATA-CON is not directly accessible via a
system technician command so there is no Test to Clear value that can be
used to directly clear errors and alarms raised against the DATA-CON.
However, since the DATA-CON and the DATA-CHLs share the same set of
tests (that is, test the same set of hardware, firmware, and software),
DATA-CON errors and alarms are accompanied by DATA-CHL errors and
alarms.
Therefore, the strategy to clear DATA-CON errors and alarms is to first clear all
DATA-CHL errors and alarms. After DATA-CHL errors and alarms have been
cleared, allow about 60 minutes for maintenance software to run internally and to
automatically clear the DATA-CON errors and alarms.
System Technician-Demanded Tests:
Descriptions and Error Codes
Because the DATA-CON uses the same set of tests as the DATA-CHLs, refer to
the "System Technician-Demanded Tests: Descriptions and Error Codes" in the
DATA-CHL (Network Control Data Channel) Maintenance documentation for a
description of the tests and their associated error codes.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-120. Network Control Driver Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board
Test to Clear
Value (a)
0
1
0 Any Any Any none
1 Local Loop Back Test (#111) MINOR ON none
257 Any Remote Maintenance Loop Around
Test (#109)
MINOR ON none
513 Crosstalk Test (#110) MINOR ON none
769 Any Dual Port RAM Test (#108) MINOR ON none