DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-205set options
8
1. The following alarm options are available:
■ Minor
Maintenance testing discovers raised alarms, downgrades them to minor
alarms, and deactivates alarmed resources. LEDs on the port board and
maintenance board follow standard minor alarm LED protocol and call
receiving OSSs.
■ Warning
Maintenance testing discovers raised alarms, downgrades them to
warnings and deactivates alarmed resources. The Alarm Log pinpoints
customer-reported trunk or station problems. Alarm LEDs light on the port
circuit pack and Maintenance circuit pack as before, but no attendant
LEDs or stations reporting alarms are affected. No call is placed to INADS.
■ Report
The report option treats alarms the same as warnings with one exception:
alarms report to INADS with a special WARNING category. When this type
of alarm is received, INADS logs the occurrence and creates a trouble
ticket or closes it immediately. Retry strategy for this type of call is similar
to normal Major or Minor alarm reports. However, the acknowledgment
LED on the attendant console or alarm reporting station does not reflect
the status of the call.
■ Yes
Alarms raise normally without filtering alarm data.
■ No
Alarms that raise on trunks, stations, or adjuncts in this category drop.
Error information displays as before, but alarm is evident. LED is inactive
and calls are not sent to INADS. Because resources are deactivated
without any record, this option is recommended only when other options
do not provide desired results.
Technicians can administer alarm options on a system-wide basis for the
following categories:
■ Major on-board station alarms
■ Minor on-board station alarms
■ Major off-board station alarms
■ Minor off-board station alarms
Trunk alarms have four alarm severity groups with administrable alarm options in
the categories listed below. For G1, technicians can administer alarm options on
a system-wide basis for the following categories:
■ Major on-board trunk alarms
■ Minor on-board trunk alarms