Maintenance Object Repair Procedures
Page 10-623EXP-INTF (Expansion Interface Circuit Pack)
10
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 FAIL Loop back on TDM Bus A failed. Loop back on TDM Bus B passed.
2 FAIL Loop back on TDM Bus B failed. Loop back on TDM Bus A passed.
3 FAIL Loop back on both TDM Busses failed.
12 FAIL Loop back on TDM Bus B failed. Loop back TDM Bus A aborted because the
system could not allocate time slots.
21 FAIL Loop back on TDM Bus A failed. Loop back on TDM Bus B aborted because
the system could not allocate time slots.
FAIL The test tone was not detected correctly after being looped through the
Expansion Interface circuit pack.
1. If error type 2305 has been logged against the Expansion Interface
circuit pack in the last 5 minutes, this test could have failed due to the
associated slips. If this is the case, first resolve the 2305 error, and then
repeat test.
2. Run the tests for the Active Tone-Clock on the Port Network that contains
the indicted Expansion Interface circuit pack to verify that dial-tone is
being supplied.
3. If the tone-clock is healthy, repeat the short test on the Expansion
Interface circuit pack.
4. If this test continues to fail, replace Expansion Interface circuit pack.
PASS Test tone was correctly detected after the internal Expansion Interface loop
back on both TDM Busses.
1. Refer to other Expansion Interface circuit pack tests if the Expansion
Interface Link is not functioning correctly.
0NO
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board (error 131).
Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (error 1538). If hyperactive, use the reset board PCSS
command.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
the board and retest.
Table 10-211. TEST #240 EI Local Loop Around Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page