Maintenance Object Repair Procedures
Page 10-414DID-TRK (DID Trunk)
10
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension, attendant number, or trunk group/member
number of the port. Use the status station, status attendant, or status
trunk command to determine the service state of the port. If the service
state indicates that the port is in use, then the port is unavailable for certain
tests. (Refer to the "Status Commands" section in Chapter 10,
"Maintenance Commands and Trouble-Clearing Aids", for a full description
of all possible states.) You must wait until the port is idle before retesting.
Attendants are always in use (off-hook) if the handset is plugged in and the
port is not busied out.
1. If the port status is active but the port is not in use (no calls), check the
Error Log for Error Type 513 (see Error Log table for description of this
error and required actions). The port may be locked up.
2. If the port status is idle, then retry the command at one-minute
intervals a maximum of five times.
3. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension, attendant number, or trunk group/member number of the port.
Use the status station, status attendant, or status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 10, "Maintenance Commands and
Trouble-Clearing Aids", for a full description of all possible states.) You
must wait until the port is idle before retesting. Attendants are always in
use (off-hook), if the handset is plugged in and the port is not busied out.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1018 ABORT Test disabled via administration. Verify that the "Maintenance Tests?" field
on the Trunk Group Form is set to "n." To enable the test, issue the change
trunk-group x command where "x" equals the number of the trunk group
to be tested. Then change the entry in the "Maintenance Tests?" field on
the form to "y."
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-134. TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page