Error Messages
Page A-65release trunk
A
If there is no tone/clock board at the specified location, one of the following messages
will be displayed:
Board not inserted
Board not assigned
If the specified cabinet carrier location is that of a switch node, the following message
will be displayed:
Switch Node carrier specified;
invalid command for SN carrier
If the cabinet carrier location entered is that of an EPN that is not available, the following
message will be displayed:
EPN is not available
If the tone/clock is not busied out and the specified action is release, the following
message will be displayed:
Object is not busied out; can’t release
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the user
to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following
message will be displayed:
All maintenance resources busy; try again later
release trunk
Help Messages
If the system technician presses HELP after entering "release trunk," the following
message will be displayed:
Enter assigned trunk group number [or group/member]
Error Messages
If the format of the identifier is invalid, the following message will be displayed: