Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-431DIG-LINE (Digital Line)
10
Notes:
a. Could experience a noisy port or link. This is an off-board problem
detected by the port circuit. Check for defective wiring, a defective voice
terminal, or move voice terminal closer to the switch (in terms of feet of
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
3. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
1 (b) 1 to 20 None WARNING OFF
18 (c) 0 busyout port
PCSSpp
WARNING OFF rel port PCSSpp
130 (d) None WARNING ON test port PCSSpp sh
257 (e) 40971 None
513 0 Station (Digital)
Audits Test (#17)
WARNING(
o)
OFF test port PCSSpp sh r 6
767 (f) 40964 None WARNING OFF
769 (g) 40963
40988
None WARNING OFF
1026(o) NONE WARNING OFF
1281 Any Station (Digital)
Audits Test (#17)
WARNING OFF test port PCSSpp sh r 4
1537 (h) 40968 None WARNING OFF
1793 Voice & Ctrl. Local
Loop Test (#13)
MINOR/
WARNING
2
ON test port PCSSpp l r 3
2049 NPE Crosstalk Test
(#9)
MINOR/
WARNING
3
ON test port PCSSpp l r 3
2304 (n) None
2305 (i) 32770 None
2305 (h) 40967 None
3840 (k) 40965 None
3840 (l) 40989 None
3841 (m) 41029 None
Table 10-140. DIG-LINE Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page