DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-696HYB-LINE (Hybrid Line)
10
Hybrid Line Ringer Update Test (#62)
In this update, a "ringer on" or a "ringer off" message is sent to the firmware to
start and stop the ringer on the set.
2000 ABORT Response to the test request was not received within the allowable time
period.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
PASS Hybrid Line Audits Test passed.
1. Although this test always return a PASS result, it may enter Error Types
257 or 513 into the Error Log. To determine if there are any problems
that don’t show up in the test result, look for these error types in the
Error Log.
2. If these errors appear in the Error Log, or if user complaints still exist,
investigate by using other circuit pack tests, and by examining the
station, wiring, and connections.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 10-232. TEST #61 Hybrid Line Audits Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page