DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-662FL-DATA (Flash Data Consistency)
10
8 FAIL The announcements are different in both SPEs. The Active SPE has the
most current announcements.
1. Issue the save announcements command to save
announcements in both SPEs. If the announcement save passes
on both SPEs, go to Step 2.
2. Run the test card-mem long again to resolve the alarms.
9 FAIL The translations and announcements are different in both SPEs. The
Active SPE is the most current.
10 FAIL The translations and announcements are different in both SPEs. The
Standby SPE has the most current translations, and the Active SPE has
the most current announcements.
1. Issue the save translations command to save translations in both
SPEs.
2. Issue the save announcements command to save
announcements in both SPEs.
3. If both the translation save and announcement save pass on both
SPEs, run the test card-mem long command again to resolve the
alarms.
12 FAIL Load vintages and announcements are different in both SPEs. The
Active SPE has the most current announcements.
1. Follow the procedures for Error Codes 4 and 8.
13 FAIL The translations, announcements, and load vintages are different in
both SPEs. The Active SPE has the most current translations and
announcements.
1. Follow the procedures for Error Codes 4 and 10.
14 FAIL The translations, announcements, and load vintages are different in
both SPEs. The Standby SPE has the most current translations, and
the Active SPE has the most current announcements.
1. Follow the procedures for Error Code 4. Be sure to issue the save
announcements command.
16 FAIL Announcements are different in both SPEs. The Standby SPE has the
most current announcements.
1. Follow the procedures for Error Code 8.
Table 10-223. TEST #421 Flash Data Consistency Check Test — Continued
Error Code
Test
Result Description/Recommendation
Continued on next page