DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-783MAINT (EPN Maintenance Circuit Pack)
10
Table 10-260. TEST #106 Sanity Handshake Test
Error
Code
Test
Result Description/Recommendation
ABORT Internal system error
1000 ABORT System resources required to run this test are not available.
2000 ABORT Response to cabinet query was not received within the allowable time
period.
2033 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2046 ABORT The EPN Maintenance circuit pack reported an invalid cabinet type. Not
knowing the cabinet type of the EPN prevents all EPN environment
maintenance from running.
1. Retry the command.
2. If the test continues to abort with 2046, then either the EPN
Maintenance circuit pack is defective, or the EPN cabinet wiring is
defective. First, replace the EPN Maintenance circuit pack.
3. If the test continues to abort with 2046, then the EPN cabinet wiring is
defective in the A carrier and the EPN Maintenance circuit pack cannot
read the backplane pins to determine the cabinet type.
10601 ABORT Test disabled via software patch.
FAIL EPN Maintenance circuit pack did not respond to Sanity Handshake and
the test timed out.
1. Verify that the carrier A power units are good. If the -5 volt unit is
defective in the A carrier, then communication with the EPN
Maintenance circuit pack is not possible.
Continued on next page