Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-292status pri-endpoint
8
Output
The following example shows the output for the status pri-endpoint 22501
command and assumes the following:
PRI endpoint ports for extension 22501 are in cabinet 1, carrier B, slot 20,
circuit 1 to 6.
The ports 1 to 3 of the specified PRI endpoint are connected on an active
call to ports 13 to 15 of board in location 1B19 (cabinet 1, carrier B, slot
19).
Ports 4 and 5 of the specified PRI endpoint are idle.
Port 6 of the specified PRI endpoint is out of service, and background
maintenance testing is being performed on the port.
NOTE:
A PRI endpoint can initiate and receive a call on any one or more of the
B-channels making up the PRI endpoint.
Note that the line listing of each B-channel’s status may continue onto the next
page. The user is prompted to press the
NxtPg key to continue the display.
status pri-endpoint 22501 page 1 of 1
PRI-ENDPOINT STATUS
Extension: 22501 Width: 6
Signaling Group ID: 3 B-Channels Active: 3
Originating Auto Restoration? n B-Channels Idle: 2
Port Service State Test In Progress Connected Port
01B2001 in-service/active n 01B1913
01B2002 in-service/active n 01B1914
01B2003 in-service/active n 01B1915
01B2004 in-service/idle n
01B2005 in-service/idle n
01B2006 out-of-service-NE y
Command Successfully Completed