Maintenance Object Repair Procedures
Page 10-813MET-LINE (MET Line)
10
2100 ABORT Could not allocate the necessary system resources to run this
test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, escalate the problem.
FAIL Battery Feed Test failed. This port is out-of-service.
1. Other ports on this circuit pack are not affected. Place user
on a different port, if available, until a replacement circuit
pack can be obtained.
2. Replace circuit pack when available.
PASS Battery Feed Test passed. Current flow is properly detected for
this port.
1. If users are reporting problems, examine connections to the
port.
2. Escalate the problem.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use
the list config command, and resolve any problems that are
found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the port.
If this is not the case, check to ensure that there is a valid
board inserted.
Table 10-272. TEST #35 Port Diagnostic Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page