Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-67reset interface
A
Error Messages
If the format of the board location is incorrect, the following error message will be
displayed:
Port/Board invalid
If the EPN on which the specified board is not available, the following message will be
displayed:
EPN is not available
If a board is not inserted in the specified location, then the following message will be
displayed:
Board not assigned
If the specified board is active, the following message will be displayed:
Illegal command for active object;
use ’set’ to switch to standby
If a reset is attempted on an invalid board in the service slot, the following message is
displayed:
Board invalid
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the user
to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following
message will be displayed:
All maintenance resources busy; try again later
reset interface
Help Messages
If you press HELP after entering "reset interface," the following message displays:
Enter identifier: [cabinet(1)];carrier(A-B);position(1-2)