Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-834MODEM-PT (Modem Pool Port)
10
descriptions for those maintenance objects (MOs) should be consulted when
repairing Combined Modem Pool arrangements.
Modem Pool NPE Crosstalk Test (#96)
This test is destructive.
This NPE Crosstalk Test verifies that the NPE is connected only to the desired
time slot and is not crosstalking on other time slots. This test operates exactly like
Test #6 for other types of port circuits but is performed twice in order to test both
NPEs in the Modem Pool Port.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
Modem Pool NPE Crosstalk Test (#96) X D
Modem Pool Conference Test (#97) X D
Modem Pool Conversion Resource Loop Around Test (#98) X X ND
Modem Pool Audits Test (#99) X X ND
Table 10-278. TEST #96 Modem Pool NPE Crosstalk Test
Error
Code
Test
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at one minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The port
may be in use on a valid call. Determine whether the port is available for
testing.
1. Retry the command at one minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at one minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
Continued on next page