Error Messages
Page A-64release tone-clock
A
If the port network on which the desired TDM bus resides is unavailable, the following
message will be displayed:
EPN is not available
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the user
to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following
message will be displayed:
All maintenance resources busy; try again later
release tone-clock
Help Messages
If the system technician presses HELP after entering "release tone-clock," the following
message will be displayed:
Enter tone/clock location:
[cabinet(1-3)];(carrier(A-E))
Error Messages
If an identifier greater than 3 (three) characters is entered, or the cabinet entered is not a
digit (number), the following message will be displayed:
Identifier invalid
If the carrier entered is invalid, the following message will be displayed:
Invalid carrier specified
If the cabinet entered is not within the valid range of cabinets or the cabinet is not
administered, the following message will be displayed:
Cabinet number not assigned