Maintenance Object Repair Procedures
Page 10-410DID-TRK (DID Trunk)
10
m. Incomplete Dial timer expired. This error applies only to the TN459.
Problem with incoming dialing stream. Refer problem to the CO.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
DID-TRK Loop Around and Conference Circuit Test,
for example, you may also
clear errors generated from subsequent tests in the testing sequence.
NPE Crosstalk Test (#6)
One or more NPEs reside on each circuit pack with a TDM Bus interface. The
NPE controls port connectivity and gain, and provides conferencing functions on
a per-port basis. The NPE Crosstalk Test verifies that this port’s NPE channel
talks on the selected time slot and never crosses over to time slots reserved for
other connections. If the NPE is not working correctly, one-way and noisy
connections may be observed. This test is usually only part of a port’s Long Test
Sequence and takes about 20 to 30 seconds to complete.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
NPE Crosstalk Test (#6) X ND
Port Diagnostic Test (#35) X X ND
Loop Around and Conference Circuit Test (#33) X ND
Port Audit Update Test (#36) X X ND
Table 10-133. TEST #6 NPE Crosstalk Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page