Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1168STBY-SPE (Standby SPE)
10
listed earlier in this section, the name of the object tested appears directly after
each test number and name.
Several of the conditions corresponding to the error codes documented here
may be detected as soon as the test <component> [[0]1] a | b [short | long]
command is issued. The net result is that none of the tests in the sequence for
the component will be attempted and a message will appear on the terminal
message line describing why the command was rejected.
The following is a list of these text strings.
Cannot interrupt Standby SPE while entering maintenance mode;
please try later
This message line error is displayed when a refresh spe-standby
command is issued while maintenance software is in the process of
putting the Standby SPE into Maintenance mode when any of the Error
Types listed in "Hardware Error Log Entries and Test to Clear Value" have
occurred and have not been resolved. It is also displayed when a system
technician-demanded test has been issued and subsequently canceled
because maintenance software is performing the Memory Functional Test,
Shadow Link Test, or M-BUS Time-out Query. Another cause may be that
maintenance software is in the process of putting the Standby SPE into
Maintenance Mode to run any other system technician-demanded test
that must be conducted on the Standby SPE in Maintenance Mode. Allow
up to 10 minutes for the maintenance software to complete its attempt to
put the Standby SPE into Maintenance Mode before issuing the refresh
spe-standby command.
Cannot perform SPE interchange; for information use status system
This message is displayed in response to the reset system interchange
command and because there are outstanding STBY-SPE errors. Display
the error log using the "dup-spe" category, and following the procedures
for all STBY-SPE errors.
Cannot reset standby SPE at this time; use the ‘status system’
command
This message is displayed when the standby SPE memory is not
refreshed. Issue the refresh spe-standby command and try the reset
again.
Could only hold Standby SPE reset because Active SPE is locked via
SPE select switches
This message is displayed when the refresh spe-standby command is
issued when the active SPE is selected via the SPE select switches.
Because the select switches disable shadowing, the refresh command
can not refresh the memory on the standby SPE. The only effect the
refresh command has is to hold the standby SPE reset.
Refresh not successful; use the ‘display errors’ and the ‘dup-spe’
category to check for standby SPE errors