DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1441UDS1-BD (UDS1 Interface Circuit Pack)
10
Notes:
a. Error 1 indicates that the circuit pack has totally stopped functioning or is
not fully administered. The alarm is logged about 15 minutes after the
circuit pack has been removed or 11 minutes after the SAKI Test (#53)
fails.
To be fully administered, a UDS1 circuit pack must meet all of these 3
conditions:
1. Have an entry in the circuit plan via the change circuit pack
command
2. Be administered via the add ds1 PCSS command
3. Be physically inserted into the correct slot
If the circuit pack has an entry in the circuit plan and either of the other two
conditions are
not
met, a MINOR alarm is logged. To resolve the error
either
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the
circuit pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been
missing for a period of 15 minutes. Warning alarms are also raised against any ports administered
on the circuit pack.
3. Minor alarms on this MO may be downgraded to warning alarms based on values set in the set
options command.
4. Major alarms on this MO may be downgraded to minor or warning alarms based on values set in
the set options command.
3841(z) 4358
3842(aa) 46097
3843(ab) 46081
3900(ac) Any CPE Loopback
Jack Test (#1212)
3901(ad) Any Far CSU
Loopback Test
(#1213)
3902(ae) Any One-Way Span
Test (#1214)
3999(af) Any None
Table 10-488. DS1 Interface Circuit Pack Maintenance Error Log Entries — Continued
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
Continued on next page