DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-142test tone-clock
A
test tone-clock
Help Messages
If the system technician presses HELP after entering "test tone-clock" the following
message will be displayed:
Enter [[cabinet(1-3)];carr(A-B)],[’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If an identifier greater than 3 (three) characters is entered, or the cabinet entered is not a
digit (number), the following message will be displayed:
Identifier invalid
If the carrier entered is invalid, the following message will be displayed:
Invalid carrier specified
If the cabinet entered is not within the valid range of cabinets or the cabinet is not
administered, the following message will be displayed:
Cabinet number not assigned
If there is no tone/clock board at the specified location, one of the following messages
will be displayed:
Board not inserted
Board not assigned
If the specified cabinet carrier location is that of a switch node, the following message
will be displayed:
Switch Node carrier specified; invalid command for SN carrier
If the cabinet carrier location entered is that of an EPN that is not available, the following
message will be displayed:
EPN is not available
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the user
to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following
message will be displayed: