DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-329test card-mem
8
invokes the Memory Card Capacity Test which determines whether the memory
card is more than 98% full. This test is also invoked after the save translation
command.
In a High or Critical Reliability System, running test card-mem command for a
memory card in the standby SPE means that the standby SPE is put into the
maintenance mode and no SPE interchange is allowed through the reset system
interchange command or scheduled SPE interchange.
Output
The following example shows the output from the test card-mem a long
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field descriptions
Port Port address (cabinet-carrier-slot-circuit): cabinet 1, carrier is
A
(control carrier A in a simplex system) and either
A
or
B
(control
carriers A and B in a duplex system). The slot and circuit fields in
the port address for the 12V-PWR, CAP-MEM, and CARD-MEM
maintenance objects are always blank. The port address for
maintenance object FL-DATA is blank.
test card-mem a long SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A 12V-PWR 701 PASS
01A CARD-MEM 695 PASS
01A CARD-MEM 696 PASS
01A CARD-MEM 697 PASS
01A CARD-MEM 698 PASS
01A CARD-MEM 699 PASS
01A CARD-MEM 694 PASS
01A CARD-MEM 693 PASS
01A CAP-MEM 1014 PASS
FL-DATA 421 PASS
Command successfully completed