Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-117test eda-external-device-alrm
A
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
test eda-external-device-alrm
test environment
Help Messages
If the system technician presses HELP after entering "test environment," the following
message will be displayed:
Enter [cabinet(1-3)],[’long’ or ’short’],
[’repeat’(1-100) or ’clear’],[’schedule’]
Error Messages
If the entered cabinet location is greater than two characters or otherwise invalid, the
following error message is displayed:
Identifier invalid
If the indicated EPN is not available, the following message is displayed:
EPN is not available
If the command entered is in conflict with another currently executing command, then a
message is displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
test hardware-group
Help Messages
If the system technician presses HELP after entering "test hardware-group" the following
message will be displayed:
board cabinet carrier spe system
If the system technician presses HELP after entering "test hardware-group board" the
following message will be displayed:
Enter board location: [cabinet (1-3);
carrier (A-E);slot(00-20)]