Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-593ETR-PT (Enhanced Tone Receiver Port)
10
Notes:
a. There are two possible alarm levels for this error type: major alarm and
minor alarm. These alarm levels are dependent on the administered
thresholds for TTR, CPTR and CCTR. Each ETR port is capable of
operating an any of these.
A major alarm is raised if the total number of ports capable of TTR, CPTR
or CCTR detection currently in-service is less than or equal to 1/2 of the
administered TTR, CPTR or CCTR threshold number.
Otherwise, a minor alarm is raised. In either case, run the short test
sequence against the port (ETR-PT) and follow the error code procedures
for the individual tests.
The threshold number of ports for service is administered using the
change system-parameters maintenance command. For details, refer to
‘‘Chapter 5, "Routine Maintenance Procedures".
b. The ETR-PT lost its translation. Testing the ETR-PT is sufficient to reload its
translation. If testing the ETR port does not clear the error, then the
TN2182 circuit pack containing the defective ETR port should be replaced
at a time when it is convenient to remove a clock board from the system.
Follow the procedures described in the TONE-BD section for replacing a
tone/clock circuit pack.
c. This error indicates the (ETR-PT) Enhanced Tone Receiver port is having
problems detecting touch tones, call progress or MFC tones. If this error
type is persistently logged, then the TN2182 circuit pack containing the
defective ETR-PT should be replaced at a time it is convenient to remove a
clock board from the system. Follow the procedures described in the
TONE-BD section for replacing a tone/clock circuit pack.
d. The ETR-PT lost its translation. Testing the ETR-PT is sufficient to reload its
translation. If testing the ETR port does not clear the error, then the
TN2182 circuit pack containing the defective ETR port should be replaced
257 (b) 17666 Tone Detection
Audit Update Test
(#43)
MAJOR/
MINOR (a)
ON test port PCSSpp r 3
513 (c) any Tone Detection
Verification Test
(#42)
MAJOR/
MINOR (a)
ON test port PCSSpp r 3
Table 10-204. Enhanced Tone Receiver Port (ETR-PT) Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page