DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-485DS1-BD (DS1 Interface Circuit Pack)
10
NPE Connection Audit Test (#50):
The system sends a message to the on-board microprocessor to update the
network connectivity translation for all the Network Processing Elements (NPEs)
on the circuit pack.
1. D = Destructive, ND = Non-destructive
Misframe Alarm Inquiry Test (#145) X X ND
Translation Update Test (#146) X X ND
ICSU Status LEDs Test (#1227) X X ND
SAKI Sanity Test (#53) X D
Internal Looparound Test (#135) X D
DS1/CSU Loopback Tests X D
DS1 Board Loopback Test (#1209) X D
CSU Equipment Loopback Test
(#1210) XD
CSU Repeater Loopback Test
(#1211)
XD
CPE Loopback Jack Test (#1212) X D
Far CSU Loopback Test (#1213) X D
One-Way Span Test (#1214) X D
Inject Single Bit Error (#1215) X D
End Loopback/Span Test (#1216) X D
Table 10-161. TEST #50 NPE Connection Audit Test
Error
Code Test Result Description/ Recommendation
None
2100
ABORT System resources required for this test are not available.
Continued on next page
Table 10-160. System Technician-Demanded Tests: DS1-BD — Continued
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset
Board
Sequence
test
ds1-loop
Command D/ND
1
Continued on next page