DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-888M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386]
10
Table 10-300. TEST #161 Loop Around Test
Error
Code
Test
Result Description/ Recommendation
1 ABORT Switch hook audit timed out. No response was received from the circuit
pack for information about the switch hook state.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, replace the circuit pack and repeat
the test.
3. If the test continues to abort, escalate the problem.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
Any FAIL Internal System Error. This test should never return a failure.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to fail reset the circuit pack via the busyout
board PCSS, reset board PCSS, release board PCSS command
sequence.
3. Retry the command at one-minute intervals a maximum of five
times.
4. If the test continues to fail, escalate the problem.
PASS Call processing and Maintenance/Test Digital Port maintenance
software agree on the Maintenance/Test Digital Port hook state.
Continued on next page