DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1360TIE-DS1 (DS1 Tie Trunk)
10
1000 ABORT System resources required to run this test were not available. The port may
be busy with a valid call. Use the display port UUCSSpp command to
determine the trunk group/member number of the port. Use the status
trunk command to determine the service state of the port. If the service
state indicates that the port is in use, then the port is unavailable for certain
tests. You must wait until the port is idle before retesting.
1. If the port status is active but the port is not in use (no calls), check the
error log for error type 1025 (see the error log table for a description of
this error and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1 minute intervals for a
maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1006 ABORT The test was aborted because the trunk is out of service.
1. Use the status trunk command to verify that the trunk is out of service.
2. If the trunk is out of service, determine why.
3. If it is OK to put the trunk back in service, issue the release trunk
command to put the trunk back in service, and then retry the test.
4. If the test continues to abort, escalate the problem.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to fail, escalate the problem.
PASS Trunk translation has been updated successfully. The current trunk states
kept in the DS1 Interface circuit pack and switch software are consistent. If
the trunk is busied out, the test does not run, but it does return PASS. To
verify that the trunk is in-service:
1. Enter status trunk command to verify that the trunk is in-service. If the
trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release trunk command to put trunk back into in-service.
3. Retry the test command.
Table 10-473. TEST #36 Audit and Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page