DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1363TIE-DS1 (DS1 Tie Trunk)
10
1018 ABORT The test was disabled via translation. You may want to determine why the
test has been disabled before you enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk Administration’
screen is set to ’n.’ To enable the test, change the trunk administration
and enter ’y’ into the ’Maintenance Test’ field.
2. Repeat the test.
1020 ABORT The test did not run due to an already existing error on the specific port or
due to a more general circuit pack error.
1. Examine the error log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
2. Retry the test.
3. If the test continues to abort, escalate the problem.
1040 ABORT This test is not performed for trunk ports administered as access
endpoints.
1. Verify this port is an access endpoint by using the display port
command.
2. If the port has been administered as an access endpoint, this test
should abort.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals for a maximum of five
times.
2. If the test continues to abort, escalate the problem.
2053 ABORT/
FAIL
(1)
At least one of the following errors is found on the circuit pack: 1281: Loss
of Signal, 1793: Blue Alarm, 2049: Red Alarm, 2305: Yellow Alarm, 1537:
Hyperactivity.
1. Look for the above error types in the Hardware Error Log and follow
the procedures given in the DS1-BD tests for the listed error types.
Table 10-474. TEST #136 DS1 Tie Trunk Seizure Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page