DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1439UDS1-BD (UDS1 Interface Circuit Pack)
10
513(f) Any MIN/ WRN
3
ON
514(g) 46086 MIN/ WRN
3
ON
769(h) 46085 MIN/ WRN
3
ON
770(i) 46096 MIN/ WRN
3
ON
1025(e) 4363 NPE Audit Test
(#50)
1281 Any Loss of Signal
Alarm Inquiry Test
(#138)
MIN /WRN
3
OFF test board PCSS
1300(j) Any Loss Of Signal
Alarm Inquiry Test
(#138)
WARNING OFF test board PCSS
1301(k) Any Loss Of Signal
Alarm Inquiry Test
(#138)
WARNING OFF test board PCSS
1302(l) Any Loss Of Signal
Alarm Inquiry Test
(#138)
MIN/ WRN
3
OFF test board PCSS
1303(m) Any Loss Of Signal
Alarm Inquiry Test
(#138)
MIN/ WRN
3
ON test board PCSS
1310(n) Any Board Loopback
Test (#1209)
MINOR ON test ds1-loop PCSS
ds1/csu-loopback-tests
1311(o) Any Equipment
Loopback Test
(#1210)
MIN/ WRN
3
OFF test ds1-loop PCSS
ds1/csu-loopback-tests
1312(p) Any Repeater
Loopback Test
(#1211)
MIN/ WRN
3
OFF test ds1-loop PCSS
ds1/csu-loopback-tests
1313(q) Any CPE Loopback
Jack Test (#1212)
MIN/ WRN
3
OFF test ds1-loop PCSS
end-loopback/span-test
1314(r) Any Far CSU
Loopback Test
(#1213)
MIN/ WRN
3
OFF test ds1-loop PCSS
end-loopback/span-
1320 Any Loss of Signal
Alarm Inquiry Test
(#138)
MIN/ WRN
3
OFF test board PCSS
Table 10-488. DS1 Interface Circuit Pack Maintenance Error Log Entries — Continued
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
Continued on next page