Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1333TDM-CLK (TDM Bus Clock)
10
TDM-CLK (TDM Bus Clock)
NOTE:
Replacing the tone/clock circuit pack requires a special procedure
described in the documentation for TONE-BD. That section also describes
the LED displays for this board.
The Time Division Multiplex (TDM) Bus Clock resides on the Tone-Clock circuit
pack, providing clocking signals both for the TDM Bus and the LAN Bus. The
Tone-Clock circuit pack is a critical component in the system and is necessary to
ensure the operation of all port circuit packs in the system. The TDM buses of the
PPN and any EPNs are synchronized together. The system timing reference can
be derived internally from the Tone-Clock circuit pack in any PN, or from an
external (off-board) timing reference. Currently, the TDM Bus Clock supports
synchronizing the TDM Bus with interface rates from Digital Signal 1 (DS1)
facilities as primary or primary and secondary references, and from Stratum 3
Clock (STRAT-3) facilities. Only the TN780 tone-clock supports a Stratum 3
clock.
Moreover, the Tone-Clock circuit pack aids in monitoring and selecting
synchronization references. The Tone-Clock circuit pack, after detecting that the
external source of timing is not valid, will automatically begin its escalation
procedure, according to the facilities administered.
NOTE:
Switching back to a DS1 source is handled by synchronization
maintenance, once any problems with it have been corrected and tested.
However, once synchronization has been switched to the internal timing
source of the master Tone-Clock circuit pack,
switching back to a Stratum 3
Clock must be initiated by a technician
after the external reference has
been repaired.
1. UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E).
MO Name (in
Alarm Log)
Alarm
Level Initial Command To Run
1
Full Name of MO
TDM-CLK MAJOR test tone-clock UUC short TDM Bus Clock
TDM-CLK MINOR test tone-clock UUC short TDM Bus Clock
TDM-CLK WARNING release tone-clock UUC TDM Bus Clock