DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-390test spe-standby
8
Feature Interactions
Testing the standby SPE maintenance object makes the standby SPE
unavailable to take over for the active SPE.
Output
The following output example for the test spe-standby command assumes that
the standby SPE is located in carrier B. The responses display on a test-by-test
basis with one line of data for each test result.
1. If no alarms are registered against the maintenance object then the test sequence is run only once. The
long clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence.
Action/Object Qualifiers Qualifier Description Permissions Defaults
Feature
Interactions
test
spe-standby
short
long
repeat
number
clear
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
Examples:
test spe-standby long
test spe-standby l
test spe-standby s r 2
test spe-standby c
init
inads
craft
Test
Sequence
= short;
Repeat = 1
See below