DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-13AC-POWER
10
Notes:
a. Refer to "POWER" for a description of this test.
b. Refer to "CARR-POW" for a description of this test.
c. Refer to "EMG-XFER” for a description of this test.
d. Refer to "CABINET" for a description of this test.
e. Refer to "EXT-DEV ADMIN? N” or "EXT-DEV ADMIN? Y" for a description of
this test.
f. Refer to "RING-GEN" for a description of this test.
AC Power Query Test (#78)
This test queries the Maintenance/Tape Processor in a PPN in a system without
High or Critical Reliability, the Duplication Interface circuit pack in a High or
Critical Reliability system PPN, or the EPN Maintenance circuit pack in an EPN
multicarrier cabinet system for the status of AC power to the switch. In a
DC-powered system, this test should never fail.
1. D = Destructive, ND = Non-destructive
Power Unit Query Test (carrier C) (#127) (b) X X ND
Emergency Transfer Query Test (#124) (c) X X ND
Cabinet Temperature Query Test (#122) (d) X X ND
External Alarm Lead Query Test (#120) (e) X X ND
Analog Ring Generator Initialization Test (#117) (f) X X ND
Analog Ring Generator Query Test (#118) (f) X X ND
Table 10-6. System Technician-Demanded Tests: AC-Power — Continued
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
Continued on next page