Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-282CLSFY-PT (Call Classifier Port)
10
Tone Detector Audit/Update Test (#43)
A sanity audit is performed on the CLSFY-PT (Call Classifier Port).
PASS Tone Detection Verification is successful. The Call Classifier Port
(CLSFY-PT) is able to detect/generate all necessary tones.
Table 10-93. Tone Detector Audit/Update Test (#43)
Error
Code
Test
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources needed for this test.
1. Wait one-minute, and repeat the command a maximum of five times.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL Hardware audit failed.
1. Run the short test sequence via the test port PCSSpp sh r 1
command.
2. If the problem persists, the system is still operating properly but
system capacity will be reduced. In order to restore system
performance to normal, replace the CLSFY-BD (Call Classifier circuit
pack) containing the defective CLSFY-PT (Call Classifier Port).
PASS The (CLSFY-PT) Call Classifier Port has passed the sanity inquiry.
Continued on next page
Table 10-92. TEST #42 Tone Detection Verification Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page