DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1555XXX-BD (Common Port Circuit Pack)
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This error indicates the circuit pack totally stopped functioning or it was
physically removed from the system. This error type is not applicable to
ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. G3iV1-1.286 or G3iV2-386 only
Common Port Circuit Pack Maintenance Error Log Entries
Error Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test board PCSS sh r 1
1(a) 0 Circuit pack
removed or SAKI
Sanity Test (#53)
MINOR ON
18(b) 0 busyout board PCSS WARNING OFF release board PCSS
23(c) 0 None WARNING OFF
36 (d) 4368 none
125 (e) None MINOR ON
217
2
(f) 0 None WARNING ON
257 65535 Control Channel Test
(#52)
MINOR ON test board PCSS sh r 20
257 (g) Any None
267 (f) 0 None WARNING ON
513 (h) Any None MINOR ON test board PCSS sh
769 (i) 4358 None
1025 (j) 4363 NPE Audit Test (#50) test board PCSS l r 20
1281 (k) Ringing Application
Test (#51)
MINOR ON test board PCSS r 2
1538 (l) Any None WARNING/
MINOR
ON
1793 (m) Neon Test (#220) MINOR ON test board PCSS r 2
3840 (n) Any None