DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-279CLSFY-PT (Call Classifier Port)
10
Notes:
a. There are two possible alarm levels for this error type: major alarm and
minor alarm. A major alarm is raised if the total number of call classifier
ports currently in-service is less than or equal to 1/2 of the administered
threshold number. Otherwise, a minor alarm is raised. In either case, run
the short test sequence against the port and follow the error code
procedures for the individual tests.
The threshold number of call classifier ports for service is administered
using the change system-parameters maintenance command. For
details, refer to Chapter 5, "Routine Maintenance Procedures".
b. The call classifier port lost its translation. Testing the call classifier port is
sufficient to reload its translation. If testing the call classifier port does not
clear the error, then the call classifier circuit pack containing the defective
call classifier port should be replaced.
c. This error indicates the call classifier port is having problems detecting
system tones (DTMF, etc.) or detecting and generating necessary
R2-MFC tones. This error should accompany some percentage of failed
calls. If this error type is persistently logged, then the call classifier circuit
pack containing the defective call classifier port should be replaced.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the
Tone
Detection Verification Test
, for example, you may also clear errors generated
from other tests in the testing sequence.
513 (c) any Tone Detection
Verification Test
(#42)
MAJOR/
MINOR (a)
ON test port PCSSpp r 3
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
Tone Detection Verification Test (#42) X X ND
Tone Detection Audit/Update Test (#43) X X ND
Table 10-91. Call Classifier Port (CLSFY-PT) Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page