DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-146list testcalls
8
Output
list testcalls
This command generates an Automatic Transmission Measurement System
(ATMS) report. The ATMS allows the voice and data trunk facilities to be
measured for satisfactory transmission performance. The performance of the
trunks is evaluated according to measurements produced by a series of analog
tests and are compared against user-defined threshold values. The purpose of
the report is to provide measurement data to help determine the quality of trunk
lines. The measurement report contains data on trunk signal loss, noise, singing
return loss, and echo return loss.
The measurements are produced by a set of analog trunk tests. The tests are
initiated by a maintenance demand test or by a set of scheduled tests. The
largest portion of these measurements are generated through scheduled testing
during system quiet hours (hours where the traffic volume is low). Each trunk test
performed by the system stores the results in a database. The trunk
measurements in this database reflect the state of each trunk at the time of its
last test.
Action/Object Qualifiers/Options Qualifier/Option Description
list testcalls
detail
summary
Detailed measurement report displayed
Summary measurement report displayed
grp group number
Measurements for a specific trunk group displayed. When used
with the
to-grp
option, this option is the starting trunk group in a
range of user-specified trunk groups.
to-grp group number
Measurements for all trunk groups from 1 to the specified
"to-grp" trunk group are displayed. When used with the
grp
option, this option is the ending trunk group in a range of
user-specified trunk groups.
mem member number
Measurements for a specific trunk group member displayed.
When used with the
to-mem
option, this option is the starting
trunk group member in a range of user-specified trunk group
members.
list suspend-alm-orig
Suspend Alarm Origination Entries
Physical Board Expires At
01C03 off-only 06/11/15:06
01E0407 on-and-off 06/11/17:26
01E0406 on-and-off 06/12/45:34