Maintenance Object Repair Procedures
Page 10-893M/T-PKT (Maintenance/Test Packet Bus Port)
10
Packet Bus Port Health Inquiry Test (#567)
This test verifies that the Packet Bus fault detection maintenance function of the
Maintenance/Test Packet Bus Port is functioning properly. This is done by having
the Maintenance/Test Packet Bus Port perform a self-test. If this self-test passes,
then the Packet Bus Port Health Inquiry Test passes. If the self-test fails, or the
SPE cannot communicate with the Maintenance/Test Packet Bus Port, then the
test fails.
Table 10-302. TEST #567 Packet Bus Port Health Inquiry Test
Error
Code
Test
Result Description/ Recommendation
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources necessary to run this test are not available.
2500 ABORT An internal operation failed; the test could not be completed.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
2059 FAIL The Maintenance/Test Packet Bus Port has reported a failure of the
on-board self-test.
2060 FAIL The Maintenance/Test Packet Bus Port has reported an invalid state for the
Packet Bus.
2061 FAIL The SPE cannot communicate with the Maintenance/Test Packet Bus Port,
but is able to communicate with the Maintenance/Test Circuit Pack.
1. Retry the command.
2. If the test continues to fail, replace the Maintenance/Test circuit pack
and retry the command.
3. If the test continues to fail, refer to PKT-BUS Maintenance
documentation to determine if the M/T-PKT failure is being caused by a
Packet Bus fault.
PASS The Maintenance/Test Packet Bus Port Packet Bus fault detection capability
is operating correctly.