DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-46ANL-16-L (16-Port Neon Analog Line)
10
40977indicates that no terminal equipment was connected when
ringing was attempted. Run the short Test via the test port
PCSSpp command, and follow the procedure for the results of Test
#48.
b. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate associated errors
(if any).
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. This is an in-line error and can only be resolved over time. This error
indicates that ringing voltage is absent. If only one Analog circuit pack in
the system has this problem, then replace the circuit pack. If only Analog
circuit packs on a particular carrier have this error, then the ringing
generator may not be connected to this carrier. If Analog circuit packs on
many carriers have this error, then it is probably a problem with the ringing
generator.
e. Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing is disturbing the customer or the terminal
equipment, it should be disabled using the change station <extension>
command. However, on some releases of the software, this action
disables Tests #6, #7, #161, and #35 as well as Test #48.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the following table when
inspecting errors in the system. By clearing error codes associated with the
Battery Feed Test,
for example, you may also clear errors generated from other
tests in the testing sequence.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
Battery Feed Test (#35) X X ND
Station Present Test (#48) X X ND
Loop Around Test (#161) X ND
Conference Test (#7) X ND
NPE Crosstalk Test (#6) X ND
Station Status and Translation Audits and Updates Test (#36) X X ND