DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-340test eda-external-device-alrm
8
Output
The following example shows the output from the test duplication-interface 1A
command, where A is the active carrier in an SPE duplex system. The responses
display on a test-by-test basis with one line of data for each test result.
Field Definitions
test eda-external-device-alrm
This command performs a hardware diagnostic test on all or specific port’s
administered external device alarms. The test PASSES if the external device
is
not
reporting an external device alarm and FAILS if the external device
is
Port The port address (cabinet-carrier); always 01A or 01B
Maintenance
Name
Always SHDW-CIR, SPE-SELE, or DUPINT.
Alt. Name Not applicable
Test No. The test being executed
Result Test result: Pass, Abort, Fail, No Board, or Disabled
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test duplication-interface a long SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
1A SHDW-CIR 285 PASS
1A SHDW-CIR 283 PASS
1A SHDW-CIR 284 PASS
1A SPE-SELE 278 PASS
1A DUPINT 315 PASS
1A DUPINT 275 PASS
1A DUPINT 276 PASS
1A DUPINT 280 PASS
1A DUPINT 271 PASS
1A DUPINT 277 PASS
1A DUPINT 272 PASS
1A DUPINT 274 PASS
1A DUPINT 273 PASS
Command Successfully Completed